FET can provide a wide array of Field Testing for project specific applications. From Windows and Doors to Curtain Wall and Skylights, we can perform the necessary on-site tests to meet job specifications and monitor product performance.
The list below is a sample of our field testing services. If you require a Test that is not listed below please contact us at 412-751-4001.
ASTM E783, Field Air Infiltration Test | Standard Test Method for Field Measurement of Air Leakage Through Installed Exterior Windows and Doors |
ASTM E1105, Field Water Penetration Test | Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference |
AAMA 501.1 Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure | Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure |
AAMA 501.2, Field Water Penetration Test | Quality assurance and diagnostic water leakage field check o installed storefronts, curtain walls, and sloped glazing systems |
AAMA 502, Field Testing of Newly Installed Fenestration Products | Test method to evaluated the performance of newly installed fenestration products for air leakage resistance and water penetration resistance |
AAMA 503, Field Testing of Storefronts, Curtain Walls and Skylights | Test method to evaluate the performance of newly installed storefronts, curtain walls, and sloped glazing systems |
AAMA 511, Water Penetration Testing of Fenestration Products | Guideline for forensic water penetration testing of fenestration products |